KXR6
 

EQUIPMENT

 

KXR6

Utilization of heat - for simultaneous heating and cooling

A distinctive feature of KXR6 systems is the availability of freon switches, thanks to which the indoor units can operate in independent modes, and the system itself can be easily installed in accordance with the layout of the building. The phonon switch is connected to the indoor unit by one line. Since each indoor units may operate on the heating and cooling, heat recovery is possible. In this case, the rooms that need to be heated, heat is supplied from the premises, which must be cooled. This allows you to significantly reduce power consumption. To the most powerful outdoor unit, you can connect up to 80 internal (16 types of hidden and open installation, various performance).

Triple pipe systems 8, 10, 12, 14, 16 HP (22,4 kW - 45,0 kW) for simultaneous heating and cooling

Model

Cooling capacity

FDC224KXRE6

22,4 kW

FDC280KXRE6

28,0 kW

FDC335KXRE6

33,5 kW

FDC400KXRE6

40,0 kW

FDC450KXRE6

45,0 kW

  • Systems with heat recovery KXR6 provides high performance in any type of buildings, working simultaneously for cooling and heating. The use of a DC compressor maximally reduced power consumption; The transfer of heat from the zones where cooling is performed to the zones where heating is required, allowed to achieve a high COP (cooling mode) - from 3.7 to 4.2.
  • The connected power of indoor units is from 50% to 200%
  • The total length of the pipeline has a record value of 1000 m, and the maximum length in one direction is up to 160 m.

Triple pipe systems 18, 20, 22, 24 HP (50,4 kW - 68,0 kW) for simultaneous heating and cooling

Model

Cooling capacity

FDC504KXRE6

50,4 kW

FDC560KXRE6

56,0 kW

FDC615KXRE6

61,5 kW

FDC680KXRE6

68,0 kW

  • Systems with heat recovery KXR6 provides high performance in any type of buildings, working simultaneously for cooling and heating. The use of a DC compressor maximally reduced power consumption; The transfer of heat from the zones where cooling is performed to the zones where heating is required, allowed to achieve a high COP (cooling mode) - from 2,6 to 3,3
  • The connected power of indoor units is from 50% to 160%.
  • The total length of the pipeline has a record value of 1000 m, and the maximum length in one direction is up to 160 m.

Triple pipe systems 26, 28, 30, 32 HP (73.5 kW - 90.0 kW) for simultaneous heating and cooling

Model

Cooling capacity

FDC735KXRE6 (FDC335-K+FDC400)

73,5 kW

FDC800KXRE6 (FDC400x2)

80,0 kW

FDC850KXRE6 (FDC400+FDC450)

85,0 kW

FDC900KXRE6 (FDC450x2)

90,0 kW

  • Systems with heat recovery KXR6 provide high performance in any type of buildings, working simultaneously for cooling and heating. The use of a DC compressor maximally reduced power consumption; The transfer of heat from the zones where cooling is performed to the zones where heating is required, allowed to achieve a high COP (cooling mode) - from 3,3 to 3,5.
  • The connected power of indoor units is from 50% to 160%.
  • The total length of the pipeline has a record value of 1000 m, and the maximum length in one direction is up to 160 m.

 